Call Now! (888) 832-3517

 

Reducing Spiral Vibration on a Genset

August 8, 2014

By Richard Livermore-Hardy, Waukesha Bearings

An Alstom 450MVA hydrogen-cooled generator operating at 3,600 rev/min and equipped with a brush gear unit showed spiral vibration with a forward rotating unbalance vector.

Spiral vibration, also known as the Newkirk effect, can be observed on various types of turbomachinery and is caused by a vibration-induced hot spot on the shaft surface generated by friction.

Potential modifications were studied by Alstom using hot spot stability analysis with a rotor dynamic model of the generator rotor, and bearing supports. Based on the calculated results, a modification of the generator shaft line was implemented using tilting pad radial bearings at the generator non-drive end and exciter end locations to shift the slip ring shaft critical speeds well above the rated speed.

Read more of the article excerpt online, or read the complete article in the July/August 2014 issue of Turbomachinery International.